Network connectivity check in Pacemaker
Posted on Mon 27 February 2012 in hints-and-kinks • 1 min read
If you want a Pacemaker cluster to move resources on changes on the network connectivity of an individual node, there are two major steps involved:
- Let Pacemaker monitor connectivity;
- Configure constraints to react on connectivity changes.
Prerequisites
Be sure to run at least Pacemaker 1.0.11 or 1.1.6 to include some
important fixes affecting the ocf:pacemaker:ping
resource agent.
Preferably, choose more than one reliable ping targets in your network (like a highly available gateway router, a core switch, or DNS server).
Pacemaker configuration
The following crm shell code snippet configures a cloned ping resource
including constraints to run Dummy resources on any node that has
connectivity at all. Please note, that the first constraint forbids to
run p_dummy1
if all nodes lose connectivity. The second constraint
places p_dummy2
on the node that has the best connectivity:
primitive p_ping ocf:pacemaker:ping \
params host_list="dns.example.com router.example.com" \
multiplier="1000" dampen="60s"\
op monitor interval="10s"
clone cl_ping p_ping
primitive p_dummy1 ocf:pacemaker:Dummy
primitive p_dummy2 ocf:pacemaker:Dummy
location l_dummy1_needs_connectivity p_dummy1 \
rule -inf: not_defined pingd or pingd lte 0
location l_dummy2_likes_best_connectivity p_dummy2 \
rule pingd: defined pingd
This article originally appeared on the hastexo.com